Medium voltage limiting includes a hybrid GDT that incorporates
a voltage clamp such as a metal oxide varistor (MOV) that
provides a maximal peak voltage of 600V. A low voltage limiting
category with 400V maximum addresses solid state technology
found in thyristor primary protectors. The AC limit is defined as
425V
rms
for all of these types of category primary protectors.
| 23 |
Digi
®
XBee
™
Cellular LTE Cat 1
CDDFN10 TVS DIODE ARRAYS
• ESD protection for high-speed
data ports
• Protects up to 4 or 6 data lines
• 2.2V to 5V working peak
reverse voltage ratings
LEARN MORE
4
The Bourns
®
Benefit
Bourns is a long-time leader in providing
proven circuit protection solutions. With
products aligned with industry standards,
Bourns' technology is available to meet
the needs of an ATIS standards-driven
design. Products based on the hybrid 5-pin
protectors are just one example of Bourns'
mature technology that can be used to meet
the most recent revision of the standards.
Evaluating a circuit for primary and
secondary protection becomes an easier
process with these new hybrid options.
Bourns is committed to superior customer
service and offers extensive engineering
expertise.
s
Figure 7: Hybrid Primary and Secondary Protector